Under normal operating conditions, the use of units should be regular gas supply pressure of nitrogen system, in addition to water oil removal filter blowdown circumstance, nitrogen purity of on-line detection and monitor nitrogen export flow. Long-term use of nitrogen machine should maintain export nitrogen purity index, such as purity drop should reduce nitrogen export flow, maintain the purity of nitrogen in order to meet the normal after a period of work, such as reducing nitrogen flow rate, nitrogen production capacity is not enough after a period of use, the nitrogen machine system should immediately enter the downtime and maintenance, replacement of adsorption tower internal adsorbent nitrogen making machine.
After the shutdown of the nitrogen generator system, an experienced manufacturer of carbon molecular sieve replacement should be immediately required for replacement and installation. The company simply introduces the replacement steps and precautions of carbon molecular sieve replacement of the nitrogen generator:
1. Firstly, stop the compressed air supply, unload the internal pressure of the nitrogen generator system until all the pressure gauges return to zero, and cut off the power of the system;
2. If the nitrogen outlet pipe is connected to the top of the adsorption tower, the nitrogen outlet pipe shall be separated first, and then the top cover of the adsorption tower shall be removed one by one;
3. Clean the carbon molecular sieve inside the filling tower filled with carbon molecular sieve;
4, check the filling tower inside the screen and palm pad is damaged;
5. Prepare for loading after checking that there is no residue in the tower packing;
6, can be in the bottom step on a layer of palm pad, and then spread 5 cm of activated alumina, and then began to fill the carbon molecular sieve;
7. Fill to the top and shock the adsorption tower with hammer or vibration equipment to ensure that the carbon molecular sieve is packed tightly.
8. Reset all equipment and parameters after loading